The CaptairFlow laminar flow hoods provide an ultra-clean and dust-free work area. Ideal for applications such as non-pathogenic cell cultures, In-vitro cultures, microbiology, PCR, homeopathic preparations, electronics, and optics. These workstations feature HEPA H14 filters to provide an ISO Class 5 work environment. The HEPA H14 filters guarantee 99.995% filtration efficiency for particles larger than 0.1µm. They also have a built-in UV light for complete chamber decontamination. Other product features include bright internal lighting, slanted sash, large opening for easy access, and side panel utility ports, and low energy consumption. Optional accessories include stainless steel or resin work surface, rolling cart with locking wheels, and stationary work bench.
OVERVIEW
The CaptairFlow laminar flow hoods provide an ultra-clean and dust-free work area. Ideal for applications such as non-pathogenic cell cultures, In-vitro cultures, microbiology, PCR, homeopathic preparations, electronics, and optics.
These workstations feature HEPA H14 filters to provide an ISO Class 5 work environment. The HEPA H14 filters guarantee 99.995% filtration efficiency for particles larger than 0.1µm. They also have a built-in UV light for complete chamber decontamination!
Other product features include bright internal lighting, slanted sash, large opening for easy access, and side panel utility ports, and low energy consumption. Optional accessories include stainless steel or resin work surface, rolling cart with locking wheels, and stationary work bench.
Applications :
- Non-pathogenic cell cultures
- In-vitro cultures
- Microbiology (Non-pathogenic)
- Homeopathic preparations in pharmacies
- Electronics
- Optics, etc.
- In-vitro cultures
- Microbiology (Non-pathogenic)
- Homeopathic preparations in pharmacies
- Electronics
- Optics, etc.
TECHNOLOGY
Working principle |
|
HEPA filtration The fan draws air from the laboratory and pass throughout the H14 HEPA filter which retains particles larger than 0.1 microns with 99.995% filtration efficiency Samples protection Air entering the enclosure is free of any external contamination and provides an ultra clean work atmosphere. Contamination sensitive samples are well protected. |
Flex Technology
The modular conception of our CaptairFlow clean air enclosures filtration column allows to perform handlings in a free of any external contamination and provides an ultra clean work atmosphere.
Want to know more? |
FEATURES & ACCESSORIES
Standard Equipment |
|
Control panel
Flow monitor: This device monitors the air flow and warns the user through a visual and audible alarm in case of fan failure.
|
|
Internal lighting Compact tubular fluorescent lighting - 18 Watts - 500 Lux - IP 67 |
|
Energy port Located on the enclosure side panels, they allow the passage of power cables/ fluid pipes in the enclosure without discomfort for the user. |
|
Optional Equipment | |
Phenolic resin work surface Work surface with built-in retention tray, made of phenolic resin, with ergonomic edges for arm rest and a comfortable working position. High chemical and mechanical resistance. Ideal for accurate weighing operations. |
|
Work surface in stainless steel 304 L High chemical and mechanical resistance. Rounded corners to facilitate cleaning operations. Built in spill tray. |
|
Molecular filter Carbon filter for the asdorption of ambiant air VOCs (AS-BE+- F-K types, see our current pricelist) |
|
Mobicap™ Rolling cart made of anti-corrosion metallic alloy |
|
Benchcap™ Fixed work bench made of anti-corrosion metallic alloy |
|
Shelf Metallic adjustable sliding shelf for Mobicap™ and Benchcap™ |
BENEFITS
4 new models
- 4 sizes available
- Stainless steel worktop with a built in spill tray
- Rolling or fixed carts available
- Standalone enclosures that do not require HVAC connections
- Immediately operational, place where you need it in your lab
Modular filtration column / Air quality into the enclosure
- HEPA H 14 filter : 99.995% filtration efficiency for particles larger than 0.1 microns (according to the EN1822-1 standard, MPPS method).
- Vertical laminar air flow entering the enclosure protects your work from contamination
Additional chemical protection
- Advanced carbon filter will protect handlings from VOCs present into the laboratory air
- Air quality in the enclosure is ISO 5
Very low energy consumption
- The largest hood is only 261W
|
|
||
|
Reference /
Energetic consumption |
Dimensions in mm & Inch (W x D x H) |
Download the data sheet in PDF |
|
|||
CaptairFlow
321
|
Ext: 825 x 630 x 1160 Int: 764 x 549 x 866 Ext 31 1/2’’ x 24 2/3’’x 45 3/4’’ / 53’’ Int 30 1/8’’ x 21 1/2’ x 34’’ |
||
CaptairFlow
391 |
Ext: 1020 x 630 x 1160/1240 Int: 965 x 522 x 860 Ext: 39 3/8’’x24 3/4’’x45 3/4’’/ 53’’ Int: 38’’x21 1/2’’x34’' |
Flow 391.pdf | |
CaptairFlow 483 |
Ext: 1275 x 800 x 1315 Int: 1173 x 695 x 1040 Ext: 50 1/4’’x31 1/2’’x51 3/4’’ / 59 7/8’’ Int: 48 7/8’’x26 1/4’’x 41’’ |
Flow 483.pdf | |
CaptairFlow 714 |
Ext: 1800 x 800 x 1315 Int: 1765 x 695 x 1040 Ext: 71’’x31 1/2’’x51 3/4’’ / 59 7/8’’ Int: 69 1/2’’x26 1/4’’x 41’’ |
Flow 714.pdf | |
Brochure: Erlab Captair Ducltess Hoods Brochure